RPGIV @ Work

A unique site for RPG and System i Lovers

Welcome!

Hi, this site will provide all what you need in System i and RPG developments.

My Name is Chamara Withanachchi, System i Expert and RPG Developer. And in the field for last 11 years.

I hope you will find lot of valuable information from this site

Internal security object not available – Message Identifier Message CPF2247 RC6 Print E-mail
User Rating: / 0
PoorBest 
Written by Chamara Withanachchi   
Internal security object not available – Message Identifier Message CPF2247 RC6

When a message CPF2247 RC6 is occurred, there is no explanation on what a RC6 means. Below is the text that will be seen:


Message ID . . . . . . . . . : CPF2247 
Message file . . . . . . . . : QCPFMSG 
Library . . . . . . . . . : QSYS 
Message . . . . : Internal security object not available. Reason code &1.
Cause . . . . . : An internal security object is not available for one of the following reasons: 

1-Object is locked by another process. 
2-User profile does not have enough auxiliary storage. 
3-Interactive profile is damaged. 
4-Damaged object detected, it is not an interactive profile. 
5-Unable to access temporary interactive profile.

A RC6 indicates that the Password for user XXXXXXXXXX not available. This will occur as a result of system value QRETSVRSEC being set to 0 when the profile was created and the password has not been changed since the system value was changed to 1. The fix is to change the password for the profile on each of the nodes.